Micro-processor Based Portable |
|
Digital Temperature Indicator |
|
Model: HI - 8012 MP |
|
This is a compact programmable temperature indicator
which can be carried anywhere for measuring temperature
ranging from -180°C to + 1700oc. This instrument has alpha
numeric display for temperature indication. Built in 9V battery
and low battery indication. Calibrated for Thermocouples/RTDs. |
|
|
|
Salient Features:
|
|
› Temp. Range: |
-200 to +200°C, 0-400°C,0-1200°C,0-1600°C
. |
|
|
› Display: |
4½ digit LCD - Alpha Numeric |
|
|
› Type: |
K, R, Pt-100 |
|
|
› Power Supply: |
9V Rechargable Battery |
|
|
› Charging Socket: |
Built in |
|
|
› Sensor : |
Leafprobe,Airprobe, Immersion probe |
|
|
› Std. Probe length : |
P 150,300,450, 1000mm |
|
Top |
Download Brochure |
|
|
|
|
|
|
|
|
Portable Digital |
|
Temperature Indicator |
|
Model: HI - 8012 |
|
This is a compact temperature indicator which can be carriedanywhere for measuring temperature ranging from -180°C to+ 1700°C. This instrument has LCD display for temperatureindication. Built in 9V battery and low battery indication.Calibrated for Thermocouples/RTDs. |
|
|
Salient Features:
|
|
› Temp. Range: |
-200 to +200°C, 0-400°C, 0-1200°C |
|
|
› Display: |
3½ digit LCD |
|
|
› Type: |
K, Pt-100 |
|
|
› Power Supply: |
9V. Battery |
|
|
› Sensor : |
Leafprobe, Airprobe, Immersion probe |
|
|
› Std. Probe length : |
300,450,1000 mm |
|
|
|
The model Nos. 8012.MP and 8012 are suitable for measuring temperature in Molten Metals, Ovens, Furnaces, Liquids, Surface temperature,etc. These instruments can be supplied as master with NML Calibration Certificate. |
Top |
Download Brochure |
|
|
|
|
|
|
|
|
Single Set |
|
Digital Temperature Controller |
|
Model: HI - 9002 |
|
A microprocessor instrument with the most advanced technology formeasuring, data storing and printouts of temperature, humidity,voltage and current. This can be used in Research Laboratories,Processing Industries, Power Plants, etc. |
|
HI-9002-I-48V
|
Salient Features:
|
|
› Temperature: |
RTDs: - 200 to + 600°C
Thermocouple 0 - 1800°C |
|
|
› Accuracy: |
± 1°C for microprocessor models or 1% for analog models. |
|
|
› Resolution: |
1°or 0.1°C |
|
|
› Sensor: |
B, E, J, K, R, S, N, T, and RTDs |
|
|
› Display: |
1) 0.5" 7 segment LED Red for PV 2) 0.5" 7 segment LED Green for SV |
|
|
› Ambient Temp. : |
Should not exceed 70°C |
|
|
› Input Power Supply: |
230 VAC ± 10%, 50 Hz (90 to 250 V AC/DC) |
|
|
› Current Rating: |
5 Amps at 220V to resistive Load. |
|
|
› Size: |
96×96mm, [72x72mm (HI9002-72-2)],
[48×96 & 48 x 48 mm (HI9002-48-2)] |
|
|
› Relay Set 1
1 : |
1 NO & 1 NC |
|
|
› Output
2 : |
SSR optional |
|
|
› Output Signal 3 : |
4 to 20 mA, 0 - 5 VDC, 0 - 10 VDC optional |
|
|
› Accuracy : |
± 0.1% |
|
|
› Setting : |
Feather Touch Keys |
|
|
Temperature Indicators are available in Single Channel or Multi Channel with selector switch. |
Top |
Download Brochure |
|
|
|
|
|
|
|
|
Two Set |
|
Digital Temperature Controller |
|
Model: HI - 9002 - 2 |
|
|
|
Salient Features:
|
|
› Temperature: |
RTDs: - 200 to + 600°C
Thermocouple 0- 1800°C |
|
|
› Accuracy: |
± 1°C for microprocessor models or 1% for analog models. |
|
|
› Resolution: |
1°or 0.1°C |
|
|
› Sensor: |
B, E, J, K, R, S, N, T, and RTDs |
|
|
› Display: |
1) 0.5" 7 segment LED Red for PV 2) 0.5" 7 segment LED Green for SV |
|
|
› Ambient Temp. : |
Should not exceed 70°C |
|
|
› Input Power Supply: |
230 VAC ± 10%, 50 Hz (90 to 250 V AC/DC) |
|
|
› Current Rating: |
5 Amps at 220V to resistive Load. |
|
|
› Size: |
96×96 (HI-9002-2-96) 72x72 (HI-9002-2-72),
48×96 mm (HI-9002-48V) (HI-9002-48H) |
|
|
› Relay Set 1 : |
1 NO & 1 NC |
|
|
› Relay Set 2 : |
1 NO & 1 NC |
|
|
› Output Signal : |
4 to 20 mA, 0 - 5V DC, 0 - 10 VDC equal to fullscale |
|
|
› Accuracy : |
± 0.1% |
|
|
Top |
Download Brochure |
|
|
|
|
|
With Timer & Counter |
|
Temperature Controller |
|
Model: HI - 9002 - 3 |
|
This is a micro controller instrument with 3-in-one combination in compact size. |
|
|
Salient Features: |
|
1. Temperature |
|
|
|
› Temperature: |
RTDs: - 200 to + 600°C
Thermocouple 0- 1800°C |
|
|
› Type: |
B, E, J, K, R, S, N, T, & RTDs |
|
|
› Display: |
3½ digit 7 seg Red |
|
|
› Relay: |
1 NO 1 NC or SSR Optional |
|
|
2. Timer |
|
|
|
› Range: |
0-99 secs/mins/hrs |
|
|
› Display: |
3% digit 7 seg LED green |
|
|
› Relay: |
1 NO & 1 NC |
|
|
2. Counter |
|
|
|
› Range: |
0-1999 |
|
|
› Display: |
3% digit 7 seg LED Red |
|
|
› Relay: |
1 NO & 1 NC |
|
|
› Power Supply : |
90 - 250 V AC/DC or 230 VAC ± 10%,50 Hz.. |
|
|
› Size: |
96×96 mm |
Top |
Download Brochure |
|
|
|
|
|
|
|
|
|
|
Model: HI - 9020 MP |
|
This is a micro-processor instrument designed to read thehumidity. |
|
|
|
Salient Features:
|
|
› Humidity Range: |
0 to 99% RH
. |
|
|
› Sensor Input: |
4 to 20 mA / HS 99 |
|
|
› Accuracy: |
± 3% |
|
|
› Power Supply: |
230V AC, 50 Hz(90 to 250V AC/DC) |
|
|
› Panel Cutout: |
48 × 48 mm or 96 × 96 mm (HI-9020-96) |
|
|
› Relay : |
1 NO & 1 NC |
|
|
Top |
Download Brochure |
|
|
|
|
|
|
With Deviation Meter |
|
Blind Temperature Controller |
|
Model: HI - 8009 |
|
Non indicating controller. Temperature is set by potentiometerthrough a circular dial. Auto cold junction compensation is built in. |
|
|
|
Salient Features:
|
|
› Range: |
100,400, 1200, 1600°C
. |
|
|
› Calibrated Scale length: |
140 mm |
|
|
› Control differential : |
± 0.25% of the span |
|
|
› Proportional action : |
Built in |
|
|
› Calibrated Accuracy: |
±0.5% |
|
|
› External Resistance : |
100 ohm max. |
|
|
› Power Supply: |
230V AC, 50 Hz |
|
|
› Panel Cutout: |
90 × 90 mm or [72 × 72 mm (HI8009-72)] [48 × 48 mm (HI-8009-48)] |
Top |
|
Download Brochure |